MassSTAR - automation for clinical diagnostics
MassSTAR is a walkaway solution designed for automating clinical LC-MS/MS and HPLC sample preparation with Chromsystems assays.
The solution has been developed with clinical laboratories in mind, offering flexibility and superior user comfort including a cutting edge software.
The complete testing menu you will find below.
Latest additions to the MassSTAR testing menu
Vitamins A and E by HPLC
The assay allows for the simultaneous quantitative determination of vitamin A (retinol) and vitamin E (α-tocopherol) in human serum or plasma samples by HPLC. Analytes are released from their transport proteins or lipoproteins through precipitation. They are then chromatographically separated in a single isocratic HPLC run and quantified using a UV detector.
- Option to use HPLC columns at ambient temperature or at 35 °C
- No cooling of eluates required
- No precolumn necessary
- No UHPLC needed
- Short run time of under 3 minutes


Vitamins B1 and B6 by (U)HPLC
The assay enables simultaneous determination of the active forms of vitamin B1 (TPP) and vitamin B6 (PLP) in human whole blood using HPLC or UHPLC. During sample preparation, analytes are derivatised, eliminating the need for traditional post-column derivatisation. The substances are then chromatographically separated using a binary gradient in either HPLC or UHPLC.
- Internal standard for each parameter
- High sample throughput
- No post-column derivatisation required
- For HPLC and UHPLC


The complete MassSTAR testing menu
Vitamins A and E by HPLC (order no. 34400-DWP)
Vitamin A (Retinol), Vitamin E (α-Tocopherol)
Vitamins B1 and B6 by HPLC (order no. 52752/F) and UHPLC (order no. 52952/UHPLC/F)
Vitamin B1 (TPP, Thiamine Pyrophosphate), Vitamin B6 (PLP, Pyridoxal 5’-Phosphate)
MassTox® TDM Series A
Antidepressants 1/EXTENDED (order no. 92713/XT)
Citalopram, N-Desmethylcitalopram, Duloxetine, Fluoxetine, Desmethylfluoxetine, Fluvoxamine, Mirtazapine, N-Desmethylmirtazapine, Paroxetine, Sertraline, N-Desmethylsertraline, Venlafaxine, O-Desmethylvenlafaxine
Antidepressants 2/Psychostimulants/EXTENDED (order no. 92715/XT)
Atomoxetine, Bupropion, Erythro-Dihydrobupropion, Threo-Dihydrobupropion, Hydroxybupropion, Clomethiazole, Dosulepin, N-Desmethyldosulepin, Methylphenidate, Mianserin, Milnacipran, Moclobemide, Opipramol, Reboxetine, Ritalinic acid, Tianeptine, Tranylcypromine, Trazodone, Vilazodone, Vortioxetine
Antiepileptic Drugs All-in-One Method (order no. 92721/XT)
Brivaracetam, Carbamazepine, Carbamazepine-10,11-epoxide, 10-OH-Carbamazepine, 10,11-Dihydroxycarbamazepine, N-Desmethylmesuximide, Ethosuximide, Felbamate, Gabapentin, Lacosamide, Lamotrigine, Levetiracetam, Oxcarbazepine, Perampanel, Phenobarbital, Phenylethylmalonamide (PEMA), Phenytoin, Pregabalin, Primidone, Rufinamide, Stiripentol, Sultiame, Theophylline, Tiagabine, Topiramate, Valproic acid, Vigabatrin, Zonisamide
Antimycotic Drugs/EXTENDED (order no. 92722/XT)
Anidulafungin, Caspofungin, Fluconazole, 5-Flucytosine, Isavuconazole, Itraconazole, Hydroxyitraconazole, Ketoconazole, Micafungin, Posaconazole, Voriconazole
Mycophenolic Acid (order no. 92716)
Mycophenolic acid, Mycophenolic acid glucuronide
Neuroleptics 1/EXTENDED (order no. 92712/XT)
Aripiprazole, Dehydroaripiprazole, Clozapine, N-Desmethylclozapine, Haloperidol, Olanzapine, N-Desmethylolanzapine, Quetiapine, Norquetiapine, Risperidone, 9-OH-Risperidone
Neuroleptics 2/EXTENDED 2 (order no. 92714/XT2)
Amisulpride, Benperidol, Brexpiprazole, Bromperidol, Cariprazine, Chlorpromazine, Chlorprothixene, Flupentixol, Fluphenazine, Guanfacine, Iloperidone, Levomepromazine, Loxapine, Lurasidone, Melperone, Perazine, Perphenazine, Pimozide, Pipamperone, Promethazine, Prothipendyl, Sertindole, Sulforidazine, Sulpiride, Thioridazine, Ziprasidone, Zotepine, Zuclopenthixol
MassTox® Immunosuppressants (order no. 93900/1200/DWP)
Cyclosporin A, Everolimus, Sirolimus, Tacrolimus
MassChrom® Vitamin D (order no. 62000/1000/F)
25-OH-Vitamin D2, 25-OH-Vitamin D3
Instrumentation and assays are supported by the Chromsystems scientific support team with extensive experience in automated clinical LC-MS/MS and HPLC.
Webinar: Automation of LC-MS/MS and HPLC workflows in clinical diagnostics
You learn how automation can improve the efficiency, accuracy and reliability of laboratory workflows. Key features include ease of use, precision, high throughput and traceability.
Webinar: Automation in Therapeutic Drug Monitoring with MassSTAR
Dr. Maximilian Dietz, Research & Development Manager at Chromsystems talks in this recorded webinar about the full CE-IVD walkaway solution MassStar that automates sample preparation in TDM.
Watch the MassSTAR video and discover more
MassSTAR allows the sample preparation of up to 288 samples per batch