Parameter Set Antidepressants 1/EXTENDED for automated sample preparation on Chromsystems MassSTAR

Order No.: 92713/XT
Parameters:
Citalopram, Desmethylfluoxetine, Duloxetine, Fluoxetine, Fluvoxamine, Mirtazapine, N-Desmethylcitalopram, N-Desmethylmirtazapine, N-Desmethylsertraline, O-Desmethylvenlafaxine, Paroxetine, Sertraline, Venlafaxine

CE-IVD compliant automation on Chromsystems MassSTAR
Encompasses 13 analytes
3PLUS1® Multilevel Calibrator Set and MassCheck® controls
Part of the continuously extended MassTox® TDM Series A

Citalopram

N-Desmethylcitalopram

Duloxetine

Fluoxetine

Desmethylfluoxetine

Fluvoxamine

Mirtazapine

N-Desmethylmirtazapine

Paroxetine

Sertraline

N-Desmethylsertraline

Venlafaxine

O-Desmethylvenlafaxine

Clinical relevance

This parameter set allows the quantitative determination of citalopram (as sum of S- and R-citalopram), N-desmethylcitalopram, duloxetine, fluoxetine, desmethylfluoxetine, fluvoxamine, mirtazapine, N-desmethylmirtazapine, paroxetine, sertraline, N-desmethylsertraline, venlafaxine and O-desmethyl-venlafaxine in human serum or plasma samples via liquid chromatography mass spectrometry (LC-MS/MS). 

It is intended as a therapeutic drug monitoring test, medically indicated for patients treated with one or more of the antidepressant drugs listed above.

 

MassTox® TDM Series A

The MassTox® TDM Series A is a modular system that enables the determination of 200 analytes without changing column or mobile phases, thereby minimising the workload in the laboratory.
It consists of 3 parts:
• MassTox® TDM Basic Kit A
• Specific MassTox® TDM Parameter Set (13 different parameter sets available)
• Analytical column MassTox® TDM MasterColumn® A

More information about MassTox® TDM Series A

 

MassSTAR

For this parameter set Chromsystems offers a CE-IVD compliant workflow method using the MassSTAR to automate the sample preparation.

More information about MassSTAR

 

Detailed performance evaluation data can be found in the appendices of the instruction manual.

More Information
Method of Analysis LC-MS/MS
Please note The information listed here, including the sample preparation, is not sufficient for using the product. Please read the information provided in the instruction manual, which includes detailed information on limitations associated with the use of the product in line with its intended purpose. Detailed performance evaluation data can be found in the appendices of the instruction manual.
Lower and Upper Limit of Quantitation

Citalopram: 2.00 – 600 µg/l
Duloxetine: 0.500 – 300 µg/l
Fluoxetine: 11.0 – 1500 µg/l
Mirtazapine: 4.00 – 900 µg/l
Paroxetine: 2.00 – 300 µg/l
Sertraline: 0.750– 450 µg/l
Venlafaxine: 7.00 – 540 µg/l

For the values of all analytes please refer to the instruction manual.

Different systems might show different performance data.

Specimen Serum/Plasma
Sample Preparation

The information on the sample preparation presented here is not sufficient for use in the laboratory. For a detailed step by step description, please refer to the instruction manual.

Automated Sample Preparation
• Load samples, calibrators, controls, reagents and required lab equipment on the MassSTAR.
• Start the automated sample preparation. *
• After completion, remove well plate from the liquid handling device, seal with a pierceable seal and transfer to autosampler.
• Inject ≤ 40 μl eluate into the LC-MS/MS system.

* Ready to use automation routine provided with the installation by Chromsystems.

Run Time 3.0 min
Injection Volume 5 – 40 µl (mass spectrometer dependent)
Flow Rate 0.6 ml/min
Column Temperature +20 to +25 °C
Gradient binary
Ionisation ESI positive
MS/MS Mode MRM
Parameters Citalopram, Desmethylfluoxetine, Duloxetine, Fluoxetine, Fluvoxamine, Mirtazapine, N-Desmethylcitalopram, N-Desmethylmirtazapine, N-Desmethylsertraline, O-Desmethylvenlafaxine, Paroxetine, Sertraline, Venlafaxine

92713/XT MassTox® TDM Parameter Set Antidepressants 1/EXTENDED
for automated sample preparation on Chromsystems MassSTAR

Order No. 92711

MassTox® TDM Basic Kit A for automated sample preparation on Chromsystems MassSTAR components
(Quantities in kit)
92001 Mobile Phase 1, 1000 ml (3x)
92002 Mobile Phase 2, 1000 ml (3x)
92003 Precipitation Reagent, 50 ml (5x)
92005 Extraction Buffer, 5 ml (5x)
92007 Dilution Buffer 1, 50 ml (5x)
92008 Dilution Buffer 2, 50 ml (5x)
92009 Rinsing Solution, 1000 ml (2x)
92056 96 Deep Well Plates, 8 pcs. (3x)
92059 Pierceable Adhesive Seals, 3 pcs. (4x)
33006 Reaction Vials, transparent, 1.5 ml, 100 pcs. (1x)

 

92913/XT MassTox® TDM Parameter Set Antidepressants 1/EXTENDED components
92029/XT 3PLUS1® Multilevel Plasma Calibrator Set Antidepressants 1/EXTENDED (lyoph.), 4 x 1 ml
0214/XT MassCheck® Antidepressants 1/EXTENDED Plasma Control, Level I (lyoph.), 5 x 1 ml
0215/XT MassCheck® Antidepressants 1/EXTENDED Plasma Control, Level II (lyoph.), 5 x 1 ml
92046/AN1/XT Internal Standard Set Antidepressants 1/EXTENDED and Neuroleptics 1/EXTENDED, consisting of:
Internal Standard Mix, 4 x 1 ml (lyoph.)
Reconstitution Buffer, 5 ml

 

Order No. Required components (not included in the kit or the parameter set)
92110 MassTox® TDM MasterColumn® A, equilibrated, with test chromatogram, 1 pc.
C5235905 High Vol. CO-RE tips, with filter, 1000 µl, 3840 pcs.
C5235903 Standard Vol. CO-RE tips, with filter, 300 µl, 5760 pcs.
92016/A1/XT Tuning Mix Antidepressants 1/EXTENDED (Analytes and Internal Standards), 1 ml

 

Order No. Lab equipment
15070 Stainless Steel Prefilter Housing, 1 pc.
15071 Stainless Steel Prefilter, 0.5 μm, 5 pcs.
33006 Reaction Vials, transparent, 1.5 ml, 100 pcs.
The following components are included in the kit:
The following products are not included in the kit but are required for the application of the method:

Citalopram

N-Desmethylcitalopram

Duloxetine

Fluoxetine

Desmethylfluoxetine

Fluvoxamine

Mirtazapine

N-Desmethylmirtazapine

Paroxetine

Sertraline

N-Desmethylsertraline

Venlafaxine

O-Desmethylvenlafaxine

Clinical relevance

This parameter set allows the quantitative determination of citalopram (as sum of S- and R-citalopram), N-desmethylcitalopram, duloxetine, fluoxetine, desmethylfluoxetine, fluvoxamine, mirtazapine, N-desmethylmirtazapine, paroxetine, sertraline, N-desmethylsertraline, venlafaxine and O-desmethyl-venlafaxine in human serum or plasma samples via liquid chromatography mass spectrometry (LC-MS/MS). 

It is intended as a therapeutic drug monitoring test, medically indicated for patients treated with one or more of the antidepressant drugs listed above.

 

MassTox® TDM Series A

The MassTox® TDM Series A is a modular system that enables the determination of 200 analytes without changing column or mobile phases, thereby minimising the workload in the laboratory.
It consists of 3 parts:
• MassTox® TDM Basic Kit A
• Specific MassTox® TDM Parameter Set (13 different parameter sets available)
• Analytical column MassTox® TDM MasterColumn® A

More information about MassTox® TDM Series A

 

MassSTAR

For this parameter set Chromsystems offers a CE-IVD compliant workflow method using the MassSTAR to automate the sample preparation.

More information about MassSTAR

 

Detailed performance evaluation data can be found in the appendices of the instruction manual.

More Information
Method of Analysis LC-MS/MS
Please note The information listed here, including the sample preparation, is not sufficient for using the product. Please read the information provided in the instruction manual, which includes detailed information on limitations associated with the use of the product in line with its intended purpose. Detailed performance evaluation data can be found in the appendices of the instruction manual.
Lower and Upper Limit of Quantitation

Citalopram: 2.00 – 600 µg/l
Duloxetine: 0.500 – 300 µg/l
Fluoxetine: 11.0 – 1500 µg/l
Mirtazapine: 4.00 – 900 µg/l
Paroxetine: 2.00 – 300 µg/l
Sertraline: 0.750– 450 µg/l
Venlafaxine: 7.00 – 540 µg/l

For the values of all analytes please refer to the instruction manual.

Different systems might show different performance data.

Specimen Serum/Plasma
Sample Preparation

The information on the sample preparation presented here is not sufficient for use in the laboratory. For a detailed step by step description, please refer to the instruction manual.

Automated Sample Preparation
• Load samples, calibrators, controls, reagents and required lab equipment on the MassSTAR.
• Start the automated sample preparation. *
• After completion, remove well plate from the liquid handling device, seal with a pierceable seal and transfer to autosampler.
• Inject ≤ 40 μl eluate into the LC-MS/MS system.

* Ready to use automation routine provided with the installation by Chromsystems.

Run Time 3.0 min
Injection Volume 5 – 40 µl (mass spectrometer dependent)
Flow Rate 0.6 ml/min
Column Temperature +20 to +25 °C
Gradient binary
Ionisation ESI positive
MS/MS Mode MRM
Parameters Citalopram, Desmethylfluoxetine, Duloxetine, Fluoxetine, Fluvoxamine, Mirtazapine, N-Desmethylcitalopram, N-Desmethylmirtazapine, N-Desmethylsertraline, O-Desmethylvenlafaxine, Paroxetine, Sertraline, Venlafaxine

92713/XT MassTox® TDM Parameter Set Antidepressants 1/EXTENDED
for automated sample preparation on Chromsystems MassSTAR

Order No. 92711

MassTox® TDM Basic Kit A for automated sample preparation on Chromsystems MassSTAR components
(Quantities in kit)
92001 Mobile Phase 1, 1000 ml (3x)
92002 Mobile Phase 2, 1000 ml (3x)
92003 Precipitation Reagent, 50 ml (5x)
92005 Extraction Buffer, 5 ml (5x)
92007 Dilution Buffer 1, 50 ml (5x)
92008 Dilution Buffer 2, 50 ml (5x)
92009 Rinsing Solution, 1000 ml (2x)
92056 96 Deep Well Plates, 8 pcs. (3x)
92059 Pierceable Adhesive Seals, 3 pcs. (4x)
33006 Reaction Vials, transparent, 1.5 ml, 100 pcs. (1x)

 

92913/XT MassTox® TDM Parameter Set Antidepressants 1/EXTENDED components
92029/XT 3PLUS1® Multilevel Plasma Calibrator Set Antidepressants 1/EXTENDED (lyoph.), 4 x 1 ml
0214/XT MassCheck® Antidepressants 1/EXTENDED Plasma Control, Level I (lyoph.), 5 x 1 ml
0215/XT MassCheck® Antidepressants 1/EXTENDED Plasma Control, Level II (lyoph.), 5 x 1 ml
92046/AN1/XT Internal Standard Set Antidepressants 1/EXTENDED and Neuroleptics 1/EXTENDED, consisting of:
Internal Standard Mix, 4 x 1 ml (lyoph.)
Reconstitution Buffer, 5 ml

 

Order No. Required components (not included in the kit or the parameter set)
92110 MassTox® TDM MasterColumn® A, equilibrated, with test chromatogram, 1 pc.
C5235905 High Vol. CO-RE tips, with filter, 1000 µl, 3840 pcs.
C5235903 Standard Vol. CO-RE tips, with filter, 300 µl, 5760 pcs.
92016/A1/XT Tuning Mix Antidepressants 1/EXTENDED (Analytes and Internal Standards), 1 ml

 

Order No. Lab equipment
15070 Stainless Steel Prefilter Housing, 1 pc.
15071 Stainless Steel Prefilter, 0.5 μm, 5 pcs.
33006 Reaction Vials, transparent, 1.5 ml, 100 pcs.
The following components are included in the kit:
The following products are not included in the kit but are required for the application of the method: