3PLUS1® Multilevel Plasma Calibrator Set Itraconazole/Posaconazole/Voriconazole

Order No.: 27029
Parameters:
Hydroxyitraconazole, Itraconazole, Posaconazole, Voriconazole

3PLUS1® Multilevel Plasma Calibrator Set Itraconazole, Posaconazole, Voriconazole, lyophilised

These lyophilised calibrators from Chromsystems are based on human plasma and should be used according to the instruction manual. They are designed according to the recommendations of the FDA to calibrate the measurement method in clinical diagnostics for the quantitative determination of itraconazole, posaconazole and voriconazole in serum/plasma. While following the instructions the calibrators should be handled and measured in the same manner as a patient specimen.
These calibrators are only available as multilevel calibrator set with 3 different concentration levels plus 1 blank value.

More Information
Content 4 x 1 ml (lyoph.)
Concentrations

Please note: Concentration values shown here are typical. For lot specific concentration values please refer to the product insert supplied with the materials. The product inserts can also be requested from us directly or downloaded from our website after login.

Substance Calibrator 1
(mg/l)
Calibrator 2
(mg/l)
Calibrator 3
(mg/l)
Blank Calibrator
(mg/l)
Itraconazole 0.19 0.88 1.95 n.d.
Hydroxy-Itraconazole 0.28 1.14 2.86 n.d.
Posaconazole 0.30 2.43 5.88 n.d.
Voriconazole 0.83 2.81 5.76 n.d.

 n.d. = not detected (< LOQ)

Method of Analysis HPLC
Parameters Hydroxyitraconazole, Itraconazole, Posaconazole, Voriconazole

Download of Product Information Leaflets
For logged-in customers the product information leaflets for calibrators, controls, internal standards and tuning mixes can be downloaded from the downloadcenter.


Download of all other documents
In the below section logged-in customers can download various documents such as instruction manuals, safety data sheets, traceability chains for calibrators, and external quality assessments.
These documents can also be downloaded from the downloadcenter.

As a customer please login or register to gain full access.

3PLUS1® Multilevel Plasma Calibrator Set Itraconazole, Posaconazole, Voriconazole, lyophilised

These lyophilised calibrators from Chromsystems are based on human plasma and should be used according to the instruction manual. They are designed according to the recommendations of the FDA to calibrate the measurement method in clinical diagnostics for the quantitative determination of itraconazole, posaconazole and voriconazole in serum/plasma. While following the instructions the calibrators should be handled and measured in the same manner as a patient specimen.
These calibrators are only available as multilevel calibrator set with 3 different concentration levels plus 1 blank value.

More Information
Content 4 x 1 ml (lyoph.)
Concentrations

Please note: Concentration values shown here are typical. For lot specific concentration values please refer to the product insert supplied with the materials. The product inserts can also be requested from us directly or downloaded from our website after login.

Substance Calibrator 1
(mg/l)
Calibrator 2
(mg/l)
Calibrator 3
(mg/l)
Blank Calibrator
(mg/l)
Itraconazole 0.19 0.88 1.95 n.d.
Hydroxy-Itraconazole 0.28 1.14 2.86 n.d.
Posaconazole 0.30 2.43 5.88 n.d.
Voriconazole 0.83 2.81 5.76 n.d.

 n.d. = not detected (< LOQ)

Method of Analysis HPLC
Parameters Hydroxyitraconazole, Itraconazole, Posaconazole, Voriconazole

Download of Product Information Leaflets
For logged-in customers the product information leaflets for calibrators, controls, internal standards and tuning mixes can be downloaded from the downloadcenter.


Download of all other documents
In the below section logged-in customers can download various documents such as instruction manuals, safety data sheets, traceability chains for calibrators, and external quality assessments.
These documents can also be downloaded from the downloadcenter.

As a customer please login or register to gain full access.