MassChrom® Amino Acid Analysis in Plasma/Serum with Reaction Vials - LC-MS/MS

Order No.: 75111, for 3 x 96 tests
Parameters:
Amino Acids

Quantitative Amino Acid Analysis (AAA) of 48 Amino Acids
Full test menu in less than 20 min or PKU/MSUD panel in 8-9 min
Sample prep with reaction vials

CE-IVD validated product ready for IVDR within timeframes and transition periods specified by the IVDR 2017/746

Acetyltyrosine
Adenosylhomocysteine
Alanine
β-Alanine
α-Aminoadipic acid
α-Aminobutyric acid
β-Aminoisobutyric acid
γ-Aminobutyric acid
Anserine
Arginine
Argininosuccinic acid
Asparagine
Aspartic acid
Carnosine
Citrulline
Homocitrulline
Cystathionine
Cystine
Cysteine S-sulfate
Homocystine
Ethanolamine
Phosphoethanolamine
Glutamic acid
Glutamine
Glycine
Histidine
1-Methylhistidine
3-Methylhistidine
Leucine
Isoleucine
Allo-Isoleucine
Lysine
Hydroxylysine
Methionine
Ornithine
Phenylalanine
Phosphoserine
Pipecolic acid
Proline
4-Hydroxyproline
Saccharopine
Sarcosine
Serine
Taurine
Threonine
Tryptophan
Tyrosine
Valine

The 7 analytes highlighted in red can be measured with both the full panel and the PKU/MSUD panel.

The New Standard in Amino Acid Analysis

  • Quantitative Amino Acid Analysis (AAA) of 48 analytes
  • Fast sample prep without derivatisation
  • Short run times
  • Excellent separation of isobaric analytes
  • Each analyte safeguarded by its own internal standard

MassChrom® Amino Acid Analysis (AAA) is designed for the quantitative determination of 48 amino acids in plasma/serum. It is CE0123-IVD certified and can be used for a range of applications including follow-up testing in newborn screening, therapy monitoring as well as for other amino acid testing purposes, such as aminoacidopathy diagnosis or nutritional research. The kit covers 48 of the clinically most important amino acids that are analysed with a run time of 20 min. Alternatively, the same assay allows the determination of 7 parameters for the  common metabolic diseases PKU and MSUD in 8-9 min – ideal for laboratories with a higher sample throughput. Both modes can be used without changes to the chromatographic setup or sample preparation.

The assay is available in 2 versions either with reaction vials or with 96 deep well plates.

No Derivatisation? - No Problem! 

All HPLC assays and most LC-MS/MS assays require derivatisation steps for a good separation of isobaric analytes but to also increase detector response. In contrast, the MassChrom® LC-MS/MS assay eliminates the need for derivatisation.
The benefits:

  • Faster sample prep
  • Error-prone analytical steps are omitted
  • Increased accuracy of results and higher robustness of the method

Excellent Separation of Isobaric Analytes

A number of amino acids are isobars and require a clear chromatographic separation. The sophisticated chromatographic setup of MassChrom® Amino Acid Analysis provides an efficient separation of all isobars such as Ile, Leu and Allo-Ile and works reliably for both, full panel and PKU/MSUD panel.

100% Coverage - 48 isotopically-labelled Internal Standards

Each of the 48 amino acids is safeguarded by its own isotopically-labelled internal standard. This includes also saccharopine and hydroxylysine that are custom-made and commercially not available anywhere else. The internal standards take care of a potential small variability in recovery, matrix effects and ionisation effectiveness by providing virtually identical chemical properties of the respective analyte.

Matrix-based Quality Controls and Calibrators

Quality controls and the 3PLUS1® Multilevel Calibrator Set are human-matrix based. This is aimed at simulating the composition of patient samples as closely as possible. It reflects the performance of the method with real samples and helps to minimise matrix effects.

The calibrator material from Chromsystems is also linked to a common reference, a standard of higher order, documented in a traceability chain and available on the website. Customers can also download an excel file with the values for quality controls and calibrators, eliminating the need for manual data entry. 

Short Run Times 

Standard HPLC Amino Acid Analysers use ion exchange chromatography and derivatisation with ninhydrin, requiring approximately 140-150 min for the analysis of all compounds. In contrast,  the LC-MS/MS assay from Chromsystems requires less than 20 minutes to quantify all 48 amino acids in a single run. This translates in a 7-fold increase of throughput in the laboratory. The speed of analysis can be further increased by using the shorter PKU/MSUD panel with a throughput of more than 17 samples within the same time frame of one analytical run with a standard HPLC-based assay. A switch between these 2 modes requires no changes to the chromatographic setup and can therefore be chosen flexibly depending on the sample amount and requirements.

Amino Acid Analysis - Webinars 

For more information on "Challenging the Status Quo of Amino Acid Analysis in Plasma" and "Amino Acid Analysis - The Chromsystems Way", watch our recorded webinars.


Download Brochure

You need all the facts at a glance? Then you are welcome to download our brochure. After you have filled out the following form, the respective link to download your document will be sent to the e-mail address provided.

Download Brochures Amino Acid Analysis - ChromsystemsDownload Brochures Amino Acid Analysis - Chromsystems
More Information
Method of Analysis LC-MS/MS
Number of Tests 3 x 96
Please note The freely available information on this website, in particular on the sample preparation, are not sufficient to work with our products. Please read instructions and warning notices on products and/or instruction manuals.
Lower Limit of Quantitation down to 0.1 μmol/l
Upper Limit of Quantification up to 3-fold concentration of highest calibrator
Intraassay

CV < 13 % (Full Panel)
CV < 6 % (PKU/MSUD Panel)

Interassay

CV < 10 % (Full Panel)
CV < 7 % (PKU/MSUD Panel)

Specimen Plasma/Serum
Sample Preparation
  • Pipette 25 μl sample/calibrator/MassCheck® control
    + 50 μl reconstituted Internal Standard Mix
    + 400 μl Precipitation Reagent into a reaction vial.
  • Mix for 30 s (vortex) and centrifuge for 5 min at 16000 x g.
  • Transfer 200 μl supernatant into autosampler vial.
  • Inject 2–5 μl into the LC-MS/MS system.
Run Time < 20 min (Full Panel), 8-9 min (PKU/MSUD Panel)
Injection Volume 2–5 μl
Column Temperature + 25 °C
Gradient

binary, flow gradient (Full Panel)
isocratic (PKU/MSUD Panel)

Ionisation ESI positive
MS/MS Mode MRM
Parameters Amino Acids
The following components are included in the kit:
The following products are not included in the kit but are required for the application of the method:
As a customer please login or register to gain full access.
Acetyltyrosine
Adenosylhomocysteine
Alanine
β-Alanine
α-Aminoadipic acid
α-Aminobutyric acid
β-Aminoisobutyric acid
γ-Aminobutyric acid
Anserine
Arginine
Argininosuccinic acid
Asparagine
Aspartic acid
Carnosine
Citrulline
Homocitrulline
Cystathionine
Cystine
Cysteine S-sulfate
Homocystine
Ethanolamine
Phosphoethanolamine
Glutamic acid
Glutamine
Glycine
Histidine
1-Methylhistidine
3-Methylhistidine
Leucine
Isoleucine
Allo-Isoleucine
Lysine
Hydroxylysine
Methionine
Ornithine
Phenylalanine
Phosphoserine
Pipecolic acid
Proline
4-Hydroxyproline
Saccharopine
Sarcosine
Serine
Taurine
Threonine
Tryptophan
Tyrosine
Valine

The 7 analytes highlighted in red can be measured with both the full panel and the PKU/MSUD panel.

The New Standard in Amino Acid Analysis

  • Quantitative Amino Acid Analysis (AAA) of 48 analytes
  • Fast sample prep without derivatisation
  • Short run times
  • Excellent separation of isobaric analytes
  • Each analyte safeguarded by its own internal standard

MassChrom® Amino Acid Analysis (AAA) is designed for the quantitative determination of 48 amino acids in plasma/serum. It is CE0123-IVD certified and can be used for a range of applications including follow-up testing in newborn screening, therapy monitoring as well as for other amino acid testing purposes, such as aminoacidopathy diagnosis or nutritional research. The kit covers 48 of the clinically most important amino acids that are analysed with a run time of 20 min. Alternatively, the same assay allows the determination of 7 parameters for the  common metabolic diseases PKU and MSUD in 8-9 min – ideal for laboratories with a higher sample throughput. Both modes can be used without changes to the chromatographic setup or sample preparation.

The assay is available in 2 versions either with reaction vials or with 96 deep well plates.

No Derivatisation? - No Problem! 

All HPLC assays and most LC-MS/MS assays require derivatisation steps for a good separation of isobaric analytes but to also increase detector response. In contrast, the MassChrom® LC-MS/MS assay eliminates the need for derivatisation.
The benefits:

  • Faster sample prep
  • Error-prone analytical steps are omitted
  • Increased accuracy of results and higher robustness of the method

Excellent Separation of Isobaric Analytes

A number of amino acids are isobars and require a clear chromatographic separation. The sophisticated chromatographic setup of MassChrom® Amino Acid Analysis provides an efficient separation of all isobars such as Ile, Leu and Allo-Ile and works reliably for both, full panel and PKU/MSUD panel.

100% Coverage - 48 isotopically-labelled Internal Standards

Each of the 48 amino acids is safeguarded by its own isotopically-labelled internal standard. This includes also saccharopine and hydroxylysine that are custom-made and commercially not available anywhere else. The internal standards take care of a potential small variability in recovery, matrix effects and ionisation effectiveness by providing virtually identical chemical properties of the respective analyte.

Matrix-based Quality Controls and Calibrators

Quality controls and the 3PLUS1® Multilevel Calibrator Set are human-matrix based. This is aimed at simulating the composition of patient samples as closely as possible. It reflects the performance of the method with real samples and helps to minimise matrix effects.

The calibrator material from Chromsystems is also linked to a common reference, a standard of higher order, documented in a traceability chain and available on the website. Customers can also download an excel file with the values for quality controls and calibrators, eliminating the need for manual data entry. 

Short Run Times 

Standard HPLC Amino Acid Analysers use ion exchange chromatography and derivatisation with ninhydrin, requiring approximately 140-150 min for the analysis of all compounds. In contrast,  the LC-MS/MS assay from Chromsystems requires less than 20 minutes to quantify all 48 amino acids in a single run. This translates in a 7-fold increase of throughput in the laboratory. The speed of analysis can be further increased by using the shorter PKU/MSUD panel with a throughput of more than 17 samples within the same time frame of one analytical run with a standard HPLC-based assay. A switch between these 2 modes requires no changes to the chromatographic setup and can therefore be chosen flexibly depending on the sample amount and requirements.

Amino Acid Analysis - Webinars 

For more information on "Challenging the Status Quo of Amino Acid Analysis in Plasma" and "Amino Acid Analysis - The Chromsystems Way", watch our recorded webinars.


Download Brochure

You need all the facts at a glance? Then you are welcome to download our brochure. After you have filled out the following form, the respective link to download your document will be sent to the e-mail address provided.

Download Brochures Amino Acid Analysis - ChromsystemsDownload Brochures Amino Acid Analysis - Chromsystems
More Information
Method of Analysis LC-MS/MS
Number of Tests 3 x 96
Please note The freely available information on this website, in particular on the sample preparation, are not sufficient to work with our products. Please read instructions and warning notices on products and/or instruction manuals.
Lower Limit of Quantitation down to 0.1 μmol/l
Upper Limit of Quantification up to 3-fold concentration of highest calibrator
Intraassay

CV < 13 % (Full Panel)
CV < 6 % (PKU/MSUD Panel)

Interassay

CV < 10 % (Full Panel)
CV < 7 % (PKU/MSUD Panel)

Specimen Plasma/Serum
Sample Preparation
  • Pipette 25 μl sample/calibrator/MassCheck® control
    + 50 μl reconstituted Internal Standard Mix
    + 400 μl Precipitation Reagent into a reaction vial.
  • Mix for 30 s (vortex) and centrifuge for 5 min at 16000 x g.
  • Transfer 200 μl supernatant into autosampler vial.
  • Inject 2–5 μl into the LC-MS/MS system.
Run Time < 20 min (Full Panel), 8-9 min (PKU/MSUD Panel)
Injection Volume 2–5 μl
Column Temperature + 25 °C
Gradient

binary, flow gradient (Full Panel)
isocratic (PKU/MSUD Panel)

Ionisation ESI positive
MS/MS Mode MRM
Parameters Amino Acids
The following components are included in the kit:
The following products are not included in the kit but are required for the application of the method: