Sultiame, Lamotrigine Serum Control, Bi-Level (I+II)

Order No.: 0064
Parameters:
Carbamazepine-10,11-epoxide, Lamotrigine, N-Desmethylmesuximide, Sultiame
 

 0064 Sultiame, Lamotrigine Serum Control, Bi-Level I + II (lyoph.)
(Sultiame, Lamotrigine, Carbamazepine-10,11-epoxide, Desmethylmesuximide), 2 x 5 x 2 ml

These lyophilised quality controls from Chromsystems are based on human serum and should be used according to the instruction manual. They are designed to monitor the accuracy and precision of analytical procedures in clinical diagnostics for the quantitative determination of sultiame, lamotrigine, carbamazepine-10,11-epoxide and desmethylmesuximide in serum/plasma. While following the instructions the controls should be handled and measured in the same manner as a patient specimen.

More Information
Content 2 x 5 x 2 ml (lyoph.)
Concentrations

Please note: Concentration values shown here are typical. For lot specific concentration values please refer to the product insert supplied with the materials. The product inserts can also be requested from us directly or downloaded from our website after login.

SubstanceValue Level I [mg/l]Range Level I [mg/l]Value Level II [mg/l]Range Level II [mg/l]
Sultiame 4.55 3.64-5.46 9.42 7.54-11.3
Carbamazepine-10, 11-epoxide 2.23 1.78-2.68 6.44 5.15-7.73
Lamotrigine 2.52 2.02-3.02 10.8 8.64-13.0
Desmethylmesuximide 8.58 6.86-10.3 32.4 25.9-38.9
Method of Analysis HPLC
Parameters Carbamazepine-10,11-epoxide, Lamotrigine, N-Desmethylmesuximide, Sultiame

Download of Product Information Leaflets
For logged-in customers the product information leaflets for calibrators, controls, internal standards and tuning mixes can be downloaded from the downloadcenter.


Download of all other documents
In the below section logged-in customers can download various documents such as instruction manuals, safety data sheets, traceability chains for calibrators, and external quality assessments.
These documents can also be downloaded from the downloadcenter.

As a customer please login or register to gain full access.

 0064 Sultiame, Lamotrigine Serum Control, Bi-Level I + II (lyoph.)
(Sultiame, Lamotrigine, Carbamazepine-10,11-epoxide, Desmethylmesuximide), 2 x 5 x 2 ml

These lyophilised quality controls from Chromsystems are based on human serum and should be used according to the instruction manual. They are designed to monitor the accuracy and precision of analytical procedures in clinical diagnostics for the quantitative determination of sultiame, lamotrigine, carbamazepine-10,11-epoxide and desmethylmesuximide in serum/plasma. While following the instructions the controls should be handled and measured in the same manner as a patient specimen.

More Information
Content 2 x 5 x 2 ml (lyoph.)
Concentrations

Please note: Concentration values shown here are typical. For lot specific concentration values please refer to the product insert supplied with the materials. The product inserts can also be requested from us directly or downloaded from our website after login.

SubstanceValue Level I [mg/l]Range Level I [mg/l]Value Level II [mg/l]Range Level II [mg/l]
Sultiame 4.55 3.64-5.46 9.42 7.54-11.3
Carbamazepine-10, 11-epoxide 2.23 1.78-2.68 6.44 5.15-7.73
Lamotrigine 2.52 2.02-3.02 10.8 8.64-13.0
Desmethylmesuximide 8.58 6.86-10.3 32.4 25.9-38.9
Method of Analysis HPLC
Parameters Carbamazepine-10,11-epoxide, Lamotrigine, N-Desmethylmesuximide, Sultiame

Download of Product Information Leaflets
For logged-in customers the product information leaflets for calibrators, controls, internal standards and tuning mixes can be downloaded from the downloadcenter.


Download of all other documents
In the below section logged-in customers can download various documents such as instruction manuals, safety data sheets, traceability chains for calibrators, and external quality assessments.
These documents can also be downloaded from the downloadcenter.

As a customer please login or register to gain full access.