Amiodarone, Desethylamiodarone Plasma Controls

Order No.: 0067/0068
Parameters:
Amiodarone, Desethylamiodarone
Grouped product items
Product Name Qty
Amiodarone, Desethylamiodarone Plasma Control, Level I
Order No.: 0067
Amiodarone, Desethylamiodarone Plasma Control, Level II
Order No.: 0068

Amiodarone, Desethylamiodarone Plasma Controls, lyophilised

0067 Amiodarone, Desethylamiodarone Plasma Control Level I (lyoph.), 10 x 2 ml
0068 Amiodarone, Desethylamiodarone Plasma Control Level II (lyoph.), 10 x 2 ml

These lyophilised quality controls from Chromsystems are based on human plasma and should be used according to the instruction manual. They are designed to monitor the accuracy and precision of analytical procedures in clinical diagnostics for the quantitative determination of amiodarone and desethylamiodarone in serum/plasma. While following the instructions the controls should be handled and measured in the same manner as a patient specimen.

More Information
Concentrations

Please note: Concentration values shown here are typical. For lot specific concentration values please refer to the product insert supplied with the materials. The product inserts can also be requested from us directly or downloaded from our website after login.

SubstanceValue Level IRange Level IValue Level IIRange Level II
Amiodarone 1.00 mg/l 0.80-1.20 mg/l 2.59 mg/l 2.07-3.11 mg/l
Desethylamiodarone 1.14 mg/l 0.91-1.37 mg/l 2.85 mg/l 2.28-3.42 mg/l
Method of Analysis HPLC
Parameters Amiodarone, Desethylamiodarone

Download of Product Information Leaflets
For logged-in customers the product information leaflets for calibrators, controls, internal standards and tuning mixes can be downloaded from the downloadcenter.


Download of all other documents
In the below section logged-in customers can download various documents such as instruction manuals, safety data sheets, traceability chains for calibrators, and external quality assessments.
These documents can also be downloaded from the downloadcenter.

As a customer please login or register to gain full access.

Amiodarone, Desethylamiodarone Plasma Controls, lyophilised

0067 Amiodarone, Desethylamiodarone Plasma Control Level I (lyoph.), 10 x 2 ml
0068 Amiodarone, Desethylamiodarone Plasma Control Level II (lyoph.), 10 x 2 ml

These lyophilised quality controls from Chromsystems are based on human plasma and should be used according to the instruction manual. They are designed to monitor the accuracy and precision of analytical procedures in clinical diagnostics for the quantitative determination of amiodarone and desethylamiodarone in serum/plasma. While following the instructions the controls should be handled and measured in the same manner as a patient specimen.

More Information
Concentrations

Please note: Concentration values shown here are typical. For lot specific concentration values please refer to the product insert supplied with the materials. The product inserts can also be requested from us directly or downloaded from our website after login.

SubstanceValue Level IRange Level IValue Level IIRange Level II
Amiodarone 1.00 mg/l 0.80-1.20 mg/l 2.59 mg/l 2.07-3.11 mg/l
Desethylamiodarone 1.14 mg/l 0.91-1.37 mg/l 2.85 mg/l 2.28-3.42 mg/l
Method of Analysis HPLC
Parameters Amiodarone, Desethylamiodarone

Download of Product Information Leaflets
For logged-in customers the product information leaflets for calibrators, controls, internal standards and tuning mixes can be downloaded from the downloadcenter.


Download of all other documents
In the below section logged-in customers can download various documents such as instruction manuals, safety data sheets, traceability chains for calibrators, and external quality assessments.
These documents can also be downloaded from the downloadcenter.

As a customer please login or register to gain full access.