Chromsystems Heat Sealer
Easy sealing of 96 well plates
Adjustable time and temperature
Ergonomic lever
Compatible with a wide range of microplates
Fast startup
Small footprint
The heat sealer is used for sealing 96 well plates with a heat seal, and in turn, protects them from evaporation or contamination during storage. It allows the adjustment of both sealing time and temperature, and produces a visual countdown from the display during the sealing process. This ensures reliable and consistent results of the sealing process.
Assay | Method | Collection Plates 96 Well Plates |
Pierceable Heat Seals for 96 Well Plates |
MassChrom® Amino Acid Analysis in Plasma/Serum or Urine Order no. 75111/DWP - in Plasma/Serum |
LC-MS/MS | Order no. 75058 | Order no. 75060 |
MassChrom® Amino Acids and Acylcarnitines from Dried Blood / Non Derivatised Order no. 57000 (with 96 Well Plates)
Succinylacetone Upgrade Set Order no. 57111 (with 96 Well Plates) |
LC-MS/MS | Order no. 57010 | Order no. 57014 |
Vitamins A and E in Serum/Plasma |
HPLC or UHPLC | Order no. 34758 | Order no. 34760 |
MassTox® Immunosuppressants in Whole Blood Order no. 93900/1200/DWP |
LC-MS/MS | Order no. 93058 | Order no. 93060 |
Sealing temperature range | 125–200°C (1 °C increments) |
---|---|
Sealing time range | 1–9 seconds (0.5 second increments) |
Time taken to warm up to 170 °C | < 10 minutes |
Power requirements | 100–230 VAC nominal |
Dimensions | 210 x 300 x 430 mm (W x D x H) |
Weight | 7.5 kg |
The heat sealer is used for sealing 96 well plates with a heat seal, and in turn, protects them from evaporation or contamination during storage. It allows the adjustment of both sealing time and temperature, and produces a visual countdown from the display during the sealing process. This ensures reliable and consistent results of the sealing process.
Assay | Method | Collection Plates 96 Well Plates |
Pierceable Heat Seals for 96 Well Plates |
MassChrom® Amino Acid Analysis in Plasma/Serum or Urine Order no. 75111/DWP - in Plasma/Serum |
LC-MS/MS | Order no. 75058 | Order no. 75060 |
MassChrom® Amino Acids and Acylcarnitines from Dried Blood / Non Derivatised Order no. 57000 (with 96 Well Plates)
Succinylacetone Upgrade Set Order no. 57111 (with 96 Well Plates) |
LC-MS/MS | Order no. 57010 | Order no. 57014 |
Vitamins A and E in Serum/Plasma |
HPLC or UHPLC | Order no. 34758 | Order no. 34760 |
MassTox® Immunosuppressants in Whole Blood Order no. 93900/1200/DWP |
LC-MS/MS | Order no. 93058 | Order no. 93060 |
Sealing temperature range | 125–200°C (1 °C increments) |
---|---|
Sealing time range | 1–9 seconds (0.5 second increments) |
Time taken to warm up to 170 °C | < 10 minutes |
Power requirements | 100–230 VAC nominal |
Dimensions | 210 x 300 x 430 mm (W x D x H) |
Weight | 7.5 kg |