Porphyrins Urine Calibration Standard

Order No.: 44003
Parameters:
Coproporphyrin I, Coproporphyrin III, Heptacarboxyporphyrin, Hexacarboxyporphyrin, Pentacarboxyporphyrin, Uroporphyrin
Porphyrins in Urine - HPLC

Porphyrins Urine Calibration Standard, lyophilised

This lyophilised calibrator from Chromsystems is based on human urine and should be used according to the instruction manual. It is designed to calibrate the measurement method in clinical diagnostics for the quantitative determination and profiling of porphyrins in urine. While following the instructions the calibrator should be handled and measured in the same manner as a patient specimen.

More Information
Content 5 x 2 ml (lyoph.)
Concentrations

Please note: Concentration values shown here are typical. For lot specific concentration values please refer to the product insert supplied with the materials. The product inserts can also be requested from us directly or downloaded from our website after login.

SubstanceUnitValue
Uroporphyrin µg/l
nmol/l
141
170
Heptacarboxyporphyrin µg/l
nmol/l
29.4
37.3
Hexacarboxyporphyrin µg/l
nmol/l
23.2
31.2
Pentacarboxyporphyrin µg/l
nmol/l
19.2
27.4
Coproporphyrin I µg/l
nmol/l
78.7
120
Coproporphyrin III µg/l
nmol/l
192
293
Method of Analysis HPLC
Parameters Coproporphyrin I, Coproporphyrin III, Heptacarboxyporphyrin, Hexacarboxyporphyrin, Pentacarboxyporphyrin, Uroporphyrin

Download of Product Information Leaflets
For logged-in customers the product information leaflets for calibrators, controls, internal standards and tuning mixes can be downloaded from the downloadcenter.


Download of all other documents
In the below section logged-in customers can download various documents such as instruction manuals, safety data sheets, traceability chains for calibrators, and external quality assessments.
These documents can also be downloaded from the downloadcenter.

As a customer please login or register to gain full access.

Porphyrins Urine Calibration Standard, lyophilised

This lyophilised calibrator from Chromsystems is based on human urine and should be used according to the instruction manual. It is designed to calibrate the measurement method in clinical diagnostics for the quantitative determination and profiling of porphyrins in urine. While following the instructions the calibrator should be handled and measured in the same manner as a patient specimen.

More Information
Content 5 x 2 ml (lyoph.)
Concentrations

Please note: Concentration values shown here are typical. For lot specific concentration values please refer to the product insert supplied with the materials. The product inserts can also be requested from us directly or downloaded from our website after login.

SubstanceUnitValue
Uroporphyrin µg/l
nmol/l
141
170
Heptacarboxyporphyrin µg/l
nmol/l
29.4
37.3
Hexacarboxyporphyrin µg/l
nmol/l
23.2
31.2
Pentacarboxyporphyrin µg/l
nmol/l
19.2
27.4
Coproporphyrin I µg/l
nmol/l
78.7
120
Coproporphyrin III µg/l
nmol/l
192
293
Method of Analysis HPLC
Parameters Coproporphyrin I, Coproporphyrin III, Heptacarboxyporphyrin, Hexacarboxyporphyrin, Pentacarboxyporphyrin, Uroporphyrin

Download of Product Information Leaflets
For logged-in customers the product information leaflets for calibrators, controls, internal standards and tuning mixes can be downloaded from the downloadcenter.


Download of all other documents
In the below section logged-in customers can download various documents such as instruction manuals, safety data sheets, traceability chains for calibrators, and external quality assessments.
These documents can also be downloaded from the downloadcenter.

As a customer please login or register to gain full access.