6PLUS1® Multilevel Urine Calibrator Set Total Metanephrines (free + conjugated)

Order No.: 80739
Parameters:
Total 3-Methoxytyramine, Total Metanephrine, Total Normetanephrine
MassChrom® Biogenic Amines/Metabolites in Urine – LC-MS/MS

6PLUS1® Multilevel Urine Calibrator Set Total Metanephrines (free + conjugated)

For MassChrom® Biogenic Amines/Metabolites in Urine with Sample Clean Up Columns or 96 SPE Well Plate by LC-MS/MS (80700/C, 80700/96)

These lyophilised calibrators from Chromsystems are based on human urine and should be used according to the instruction manual. They are designed to calibrate the measurement method in clinical diagnostics for the quantitative determination of the total metanephrines (free + conjugated) in urine. While following the instructions the calibrators should be handled and measured in the same manner as a patient specimen.

These calibrators are only available as multilevel calibrator set with 6 different concentration levels plus 1 blank value.

 

More Information
Content 7 x 2 ml (lyoph.)
Concentrations

Please note: Concentration values shown here are typical. For lot specific concentration values please refer to the product insert supplied with the materials. The product inserts can also be requested from us directly or downloaded from our website after login.

 
Substance UnitCalibrator 1Calibrator 2Calibrator 3Calibrator 4Calibrator 5Calibrator 6Blank Calibrator
Metanephrine µg/l 
nmol/l
10.5
53.0
197
999
370
1874
557
2822
2686
13621
4875
24722
n.d.
Normetanephrine µg/l 
nmol/l

15.6
85.4

319
1744
607
3314
883
4818
4770
26037
8582
46844
n.d.
3-Methoxytyramine µg/l 
nmol/l
15.9
95.2
134
802
239
1432
345
2062
2501
14956
4723
28247
n.d.

n.d. = not determined (< LOQ)

Method of Analysis LC-MS/MS
Parameters Total 3-Methoxytyramine, Total Metanephrine, Total Normetanephrine

Download of Product Information Leaflets
For logged-in customers the product information leaflets for calibrators, controls, internal standards and tuning mixes can be downloaded from the downloadcenter.


Download of all other documents
In the below section logged-in customers can download various documents such as instruction manuals, safety data sheets, traceability chains for calibrators, and external quality assessments.
These documents can also be downloaded from the downloadcenter.

As a customer please login or register to gain full access.

6PLUS1® Multilevel Urine Calibrator Set Total Metanephrines (free + conjugated)

For MassChrom® Biogenic Amines/Metabolites in Urine with Sample Clean Up Columns or 96 SPE Well Plate by LC-MS/MS (80700/C, 80700/96)

These lyophilised calibrators from Chromsystems are based on human urine and should be used according to the instruction manual. They are designed to calibrate the measurement method in clinical diagnostics for the quantitative determination of the total metanephrines (free + conjugated) in urine. While following the instructions the calibrators should be handled and measured in the same manner as a patient specimen.

These calibrators are only available as multilevel calibrator set with 6 different concentration levels plus 1 blank value.

 

More Information
Content 7 x 2 ml (lyoph.)
Concentrations

Please note: Concentration values shown here are typical. For lot specific concentration values please refer to the product insert supplied with the materials. The product inserts can also be requested from us directly or downloaded from our website after login.

 
Substance UnitCalibrator 1Calibrator 2Calibrator 3Calibrator 4Calibrator 5Calibrator 6Blank Calibrator
Metanephrine µg/l 
nmol/l
10.5
53.0
197
999
370
1874
557
2822
2686
13621
4875
24722
n.d.
Normetanephrine µg/l 
nmol/l

15.6
85.4

319
1744
607
3314
883
4818
4770
26037
8582
46844
n.d.
3-Methoxytyramine µg/l 
nmol/l
15.9
95.2
134
802
239
1432
345
2062
2501
14956
4723
28247
n.d.

n.d. = not determined (< LOQ)

Method of Analysis LC-MS/MS
Parameters Total 3-Methoxytyramine, Total Metanephrine, Total Normetanephrine

Download of Product Information Leaflets
For logged-in customers the product information leaflets for calibrators, controls, internal standards and tuning mixes can be downloaded from the downloadcenter.


Download of all other documents
In the below section logged-in customers can download various documents such as instruction manuals, safety data sheets, traceability chains for calibrators, and external quality assessments.
These documents can also be downloaded from the downloadcenter.

As a customer please login or register to gain full access.