Chromsystems MassScreen®
Newborn Screening
EXTENDED

MassScreen® Amino Acids, Acylcarnitines EXTENDED from Dried Blood

The new extended assays allow the simultaneous determination of 62 analytes, thereby increasing the number of metabolic diseases that can be screened for in a single run. 

Validated in accordance with IVDR, the assays meet stringent regulatory requirements. A comprehensive panel of internal standards is designed to support precise and consistent measurements. The upper end of the measuring range of the MS/MS system can be determined using the new linearity sets. In addition, the newly introduced three-point controls are developed to support precision and reproducibility.

  • 62 analytes in one run, including adenosine and 2'-deoxyadenosine
  • IVDR certified
  • No derivatisation required
  • No analytical column necessary
  • Matrix-based controls at three concentration levels
  • Linearity sets for determining the upper end of the MS/MS measuring
    range

Parameter menu

Amino acids

Alanine / sarcosine*

Arginine

Argininosuccinic acid

Citrulline

Glutamine / lysine*

Glutamic acid

Glycine

Leucine / isoleucine / allo-isoleucine / hydroxyproline*

Methionine

Ornithine

Phenylalanine

Proline

Serine

Tyrosine

Valine

3-O-Methyldopa

Nucleosides

Adenosine**

2‘-Deoxyadenosine**

Ketone

Succinylacetone

Creatine and related metabolites

Creatine

Creatinine

Guanidinoacetic acid

Lysophospholipids

C20:0 LPC 1-Arachidoyl-2-hydroxy-sn-glycero-3-phosphocholine

C22:0 LPC 1-Behenoyl-2-hydroxy-sn-glycero-3-phosphocholine

C24:0 LPC 1-Lignoceroyl-2-hydroxy-sn-glycero-3-phosphocholine

C26:0 LPC 1-Hexacosanoyl-2-hydroxy-sn-glycero-3-phosphocholine

Carnitines

C0 Free carnitine

C2 Acetylcarnitine

C3 Propionylcarnitine

C3DC / C4OH Malonylcarnitine (C3DC) / 
3-hydroxybutyrylcarnitine  / 
3-hydroxyisobutyrylcarnitine (C4OH)*

C4 Butyrylcarnitine / isobutyrylcarnitine*

C4DC / C5OH Methylmalonylcarnitine / 
succinylcarnitine (C4DC) / 3-hydroxyisovalerylcarnitine / 2-methyl-3-hydroxybutyrylcarnitine (C5OH)*

C5 Isovalerylcarnitine / 2-methylbutyrylcarnitine*

C5:1 Tiglylcarnitine / 3-methylcrotonylcarnitine

C5DC / C6OH Glutarylcarnitine (C5DC) / 
3-hydroxyhexanoylcarnitine (C6OH)*

C6 Hexanoylcarnitine

C6DC Adipylcarnitine / 3-methylglutarylcarnitine*

C8 Octanoylcarnitine

C8:1 Octenoylcarnitine

C10 Decanoylcarnitine

C10:1 Decenoylcarnitine 

C10:2 Decadienoylcarnitine

C12 Dodecanoylcarnitine

C12:1 Dodecenoylcarnitine 

C14 Tetradecanoylcarnitine

C14:1 Tetradecenoylcarnitine

C14:2 Tetradecadienoylcarnitine

C14OH 3-Hydroxytetradecanoylcarnitine

C16 Hexadecanoylcarnitine

C16:1 Hexadecenoylcarnitine

C16OH 3-Hydroxyhexadecanoylcarnitine

C16:1OH / C17 3-Hydroxyhexadecenoylcarnitine (C16:1OH) / heptadecanoylcarnitine (C17)*

C18 Octadecanoylcarnitine

C18:1 Octadecenoylcarnitine

C18:2 Octadecadienoylcarnitine

C18OH 3-Hydroxyoctadecanoylcarnitine

C18:1OH 3-Hydroxyoctadecenoylcarnitine

C18:2OH 3-Hydroxyoctadecadienoylcarnitine

C20 Eicosanoylcarnitine

C22 Docosanoylcarnitine

C24 Tetracosanoylcarnitine

C26 Hexacosanoylcarnitine 


 * Isomers and isobars cannot be differentiated with these assays.

** With the MassScreen® Kits 57075-ADO and 57075-F-ADO

Sample preparation

The samples are prepared based on the effective extraction of the analytes from the dried blood spot. In the version with 96 well filter plates, a transfer step to a new plate is replaced with a centrifugation step, simplifying one step of the process.

MassScreen® Kits

There are two kit options available with or without adenosine (Ado) / 2‘-deoxyadenosine (dAdo) measurement. Each of these options are available in two ­versions with 96 well plates or 96 well filter plates. The kits contain all of the reagents and vials required for sample preparation as well as the mobile phase, internal standards and controls. There are two versions to ensure the optimal adaptation to different laboratory requirements:

  • With 96 Well Plates: the samples are transferred by pipetting
  • With 96 Well Filter Plates: the samples are transferred efficiently through centrifugation

Bestell-Nr.

Produkt





Linearity Sets

The Chromsystems Multilevel Dried Blood Spot Linearity Sets are used to determine the upper end of the MS/MS system’s linear dynamic range. They are applied to filter paper and are prepared and measured in the same way as patient samples. The linearity sets are available in two versions, with and without Ado/dAdo and are based on human whole blood.

  • Based on human matrix material (whole blood)
  • On filter paper
  • Set available with and without Ado/dAdo

  • Schedule a personalised consultation tailored to your lab’s needs
  • Place an order and discuss availability
  • Learn how the MassScreen® Amino Acids, Acylcarnitines EXTENDED from Dried Blood Assay can be integrated into your workflow

Don’t miss the opportunity to upgrade your newborn screening capabilities with a fully IVDR-compliant and efficient solution.


 

Brochure download

You need all the facts at a glance? Then you are welcome to download our brochure.
After you have filled out the following form, the respective link to download your document will be sent to the e-mail address provided.

Download Brochure Newborn Screening - ChromsystemsDownload Brochure Newborn Screening - Chromsystems
Download Brochure Newborn Screening - ChromsystemsDownload Brochure Newborn Screening - Chromsystems