AED Serum Calibration Standard

Order No.: 22005
Parameters:
Carbamazepine, Carbamazepine-10,11-epoxide, Ethosuximide, Lamotrigine, Phenobarbital, Phenytoin, Primidone
Antiepileptic Drugs in Serum/Plasma - HPLC

AED Serum Calibration Standard, lyophilised. This product is suitable for the kits with the ordering number 22000/F and 22000/HR.

This lyophilised calibrator from Chromsystems is based on human serum and should be used according to the instruction manual. It is designed to calibrate the measurement method in clinical diagnostics for the quantitative determination of antiepileptic drugs in serum/plasma. While following the instructions the calibrator should be handled and measured in the same manner as a patient specimen.

More Information
Content 5 x 1 ml (lyoph.)
Concentrations

Please note: Concentration values shown here are typical. For lot specific concentration values please refer to the product insert supplied with the materials. The product inserts can also be requested from us directly or downloaded from our website after login.

SubstanceUnitValue
Ethosuximide mg/l
µmol/l
57.8
409
Primidone mg/l
µmol/l
9.19
42.1
Lamotrigine mg/l
µmol/l
7.04
27.5
Phenobarbital mg/l
µmol/l
23.3
100
Carbamazepine-10,11-epoxide mg/l
µmol/l
2.73
10.8
Carbamazepine mg/l
µmol/l
9.39
39.7
Phenytoin mg/l
µmol/l
11.8
46.8
Method of Analysis HPLC
Parameters Carbamazepine, Carbamazepine-10,11-epoxide, Ethosuximide, Lamotrigine, Phenobarbital, Phenytoin, Primidone
As a customer please login or register to gain full access.

AED Serum Calibration Standard, lyophilised. This product is suitable for the kits with the ordering number 22000/F and 22000/HR.

This lyophilised calibrator from Chromsystems is based on human serum and should be used according to the instruction manual. It is designed to calibrate the measurement method in clinical diagnostics for the quantitative determination of antiepileptic drugs in serum/plasma. While following the instructions the calibrator should be handled and measured in the same manner as a patient specimen.

More Information
Content 5 x 1 ml (lyoph.)
Concentrations

Please note: Concentration values shown here are typical. For lot specific concentration values please refer to the product insert supplied with the materials. The product inserts can also be requested from us directly or downloaded from our website after login.

SubstanceUnitValue
Ethosuximide mg/l
µmol/l
57.8
409
Primidone mg/l
µmol/l
9.19
42.1
Lamotrigine mg/l
µmol/l
7.04
27.5
Phenobarbital mg/l
µmol/l
23.3
100
Carbamazepine-10,11-epoxide mg/l
µmol/l
2.73
10.8
Carbamazepine mg/l
µmol/l
9.39
39.7
Phenytoin mg/l
µmol/l
11.8
46.8
Method of Analysis HPLC
Parameters Carbamazepine, Carbamazepine-10,11-epoxide, Ethosuximide, Lamotrigine, Phenobarbital, Phenytoin, Primidone
As a customer please login or register to gain full access.