Automated Vitamins A and E in Serum/Plasma - HPLC
Automated sample preparation with 96 well filter plates
96 samples in less than 30 minutes
Works on a range of liquid handling devices
CE-IVD validated product ready for IVDR within timeframes and transition periods specified by the IVDR 2017/746
Vitamin A
Vitamin E
Clinical relevance
Vitamins A and E are fat-soluble vitamins, which perform important functions in the body.
Vitamin A plays an important role in vision, bone metabolism, and the synthesis of steroid hormones. Deficiency of vitamin A can lead to night blindness, skin dehydration, and hair loss.
Vitamin E protects, among others, unsaturated fatty acids in the cell membranes and the LDL cholesterol from attacks by reactive radicals, which can occur as a result of increased oxidative stress in the body. Deficiency of vitamin E can lead to permanent joint pain, making the determination of vitamin E levels essential in this case.
However, overdoses of these vitamins may cause hypervitaminosis with intoxication symptoms. In addition, chemotherapies should not be "accompanied" by extra vitamin supplements – especially high doses of vitamins A and E may limit the success of treatment.
Product advantages
- Automated sample preparation:
96 samples in less than 30 minutes
This HPLC kit allows for the automated analysis of vitamins A and E in plasma/serum. The automated preparation of 96 samples can be completed in less than 30 minutes – ideal for resource-saving processing of larger numbers of samples.
Chromsystems also offers another automated method using UHPLC.
Content for 5 x 96 tests
Mobile Phase, 5 x 1000 ml
Precipitation Reagent I, 2 x 2.5 ml
Internal Standard, 100 ml
Vitamins A and E Serum Calibration Standard (lyoph.), 2 x 5 x 1 ml
96 Well Filter Plates, 5 pcs.
96 Well Collection Plates, 5 pcs.
Pierceable Heat Seals for 96 Well Plates, 6 pcs.
Method of Analysis | HPLC |
---|---|
Number of Tests | 5 x 96 |
Please note | The freely available information on this website, in particular on the sample preparation, are not sufficient to work with our products. Please read instructions and warning notices on products and/or instruction manuals. |
Lower Limit of Quantitation | Vitamin A: 0.02 mg/l Vitamin E: 0.5 mg/l |
Upper Limit of Quantification | Vitamin A: 0.02-4.5 mg/l Vitamin E: 0.5-38 mg/l |
Intraassay | CV < 5 % |
Interassay | CV < 5 % |
Recovery | Vitamin A > 94 %; Vitamin E > 90 % |
Specimen | Serum/Plasma |
Sample Preparation |
|
Run Time | 9 min |
Injection Volume | 50 µl |
Column Temperature | ambient (~ 25°C) |
Wavelengths | 325 nm, after 3.5 min switch to 295 nm |
Parameters | Vitamin A (Retinol), Vitamin E (α-Tocopherol) |
-
Vitamins A and E Serum Calibration StandardOrder no.: 34004Vitamins A and E in Serum/Plasma- HPLC/UHPLC
-
Pierceable Heat Seals for 96 Well PlatesOrder no.: 34760Optional, as an alternative to 34459 (Cross-slitted Adhesive Seals)
-
HPLC Column Vitamins A and E in Serum/PlasmaOrder no.: 34100Vitamins A and E in Serum/Plasma - HPLC
-
Vitamins A and E Serum Calibration StandardOrder no.: 34004Vitamins A and E in Serum/Plasma- HPLC/UHPLC
-
HPLC Column Vitamins A and E in Serum/PlasmaOrder no.: 34100Vitamins A and E in Serum/Plasma - HPLC
-
Chromsystems Heat SealerOrder no.: 42740
Easy sealing of 96 well plates
Adjustable time and temperature
Ergonomic lever
Compatible with a wide range of microplates
Fast startup
Small footprint
Vitamin A
Vitamin E
Clinical relevance
Vitamins A and E are fat-soluble vitamins, which perform important functions in the body.
Vitamin A plays an important role in vision, bone metabolism, and the synthesis of steroid hormones. Deficiency of vitamin A can lead to night blindness, skin dehydration, and hair loss.
Vitamin E protects, among others, unsaturated fatty acids in the cell membranes and the LDL cholesterol from attacks by reactive radicals, which can occur as a result of increased oxidative stress in the body. Deficiency of vitamin E can lead to permanent joint pain, making the determination of vitamin E levels essential in this case.
However, overdoses of these vitamins may cause hypervitaminosis with intoxication symptoms. In addition, chemotherapies should not be "accompanied" by extra vitamin supplements – especially high doses of vitamins A and E may limit the success of treatment.
Product advantages
- Automated sample preparation:
96 samples in less than 30 minutes
This HPLC kit allows for the automated analysis of vitamins A and E in plasma/serum. The automated preparation of 96 samples can be completed in less than 30 minutes – ideal for resource-saving processing of larger numbers of samples.
Chromsystems also offers another automated method using UHPLC.
Content for 5 x 96 tests
Mobile Phase, 5 x 1000 ml
Precipitation Reagent I, 2 x 2.5 ml
Internal Standard, 100 ml
Vitamins A and E Serum Calibration Standard (lyoph.), 2 x 5 x 1 ml
96 Well Filter Plates, 5 pcs.
96 Well Collection Plates, 5 pcs.
Pierceable Heat Seals for 96 Well Plates, 6 pcs.
Method of Analysis | HPLC |
---|---|
Number of Tests | 5 x 96 |
Please note | The freely available information on this website, in particular on the sample preparation, are not sufficient to work with our products. Please read instructions and warning notices on products and/or instruction manuals. |
Lower Limit of Quantitation | Vitamin A: 0.02 mg/l Vitamin E: 0.5 mg/l |
Upper Limit of Quantification | Vitamin A: 0.02-4.5 mg/l Vitamin E: 0.5-38 mg/l |
Intraassay | CV < 5 % |
Interassay | CV < 5 % |
Recovery | Vitamin A > 94 %; Vitamin E > 90 % |
Specimen | Serum/Plasma |
Sample Preparation |
|
Run Time | 9 min |
Injection Volume | 50 µl |
Column Temperature | ambient (~ 25°C) |
Wavelengths | 325 nm, after 3.5 min switch to 295 nm |
Parameters | Vitamin A (Retinol), Vitamin E (α-Tocopherol) |
-
Vitamins A and E Serum Calibration StandardOrder no.: 34004Vitamins A and E in Serum/Plasma- HPLC/UHPLC
-
Pierceable Heat Seals for 96 Well PlatesOrder no.: 34760Optional, as an alternative to 34459 (Cross-slitted Adhesive Seals)
-
HPLC Column Vitamins A and E in Serum/PlasmaOrder no.: 34100Vitamins A and E in Serum/Plasma - HPLC
-
Vitamins A and E Serum Calibration StandardOrder no.: 34004Vitamins A and E in Serum/Plasma- HPLC/UHPLC
-
HPLC Column Vitamins A and E in Serum/PlasmaOrder no.: 34100Vitamins A and E in Serum/Plasma - HPLC
-
Chromsystems Heat SealerOrder no.: 42740
Easy sealing of 96 well plates
Adjustable time and temperature
Ergonomic lever
Compatible with a wide range of microplates
Fast startup
Small footprint