Clinical Relevance
This Sample Prep Set allows the quantitative determination of vanillylmandelic acid (VMA), homovanillic acid (HVA), 5-hydroxyindoleacetic acid (5-HIAA) in patient urine samples by LC-MS/MS. It is used for the diagnostics of neuroblastoma and carcinoid tumours.
Product advantage
- Simple and fast sample prep consisting of 2 pipetting steps and subsequent injection
- Isotopically labelled internal standard for each analyte
- 6PLUS1® Multilevel Calibrator Set and MassCheck® controls ensure high precision of results
This Sample Prep Set encompasses all required components for an efficient and fast sample preparation.
There is also a method using collection plates (80800/96 & 80800/480) as well as the corresponding fully automated workflow solution available for laboratories with a higher sample throughput.
Number of Tests | 96 |
---|---|
Limit of quantification | 0.2 - 2.6 mg/l |
Linearity | VMA, 5-HIAA up to 150 mg/l |
Recovery | 95 - 113 % |
Intraassay | CV 2.5 - 6.7 % |
Interassay | CV 3.7 - 7.7 % |
Analysis Time | 3 min |
Sample Preparation |
|
Sample Stability | The prepared samples are stable for up to 5 days (VMA and HVA) or up to 3 days ( 5-HIAA) at +2°C to +8°C in amber coloured vials. For longer storage periods keep samples frozen below -18°C. |
Specimen | 24h urine or spontaneous urine |
Pre-analytic Treatment | 24 h urine is collected in a suitable container with 10 ml of 10–25 % HCl (VMA, HVA) or 10 ml glacial acetic acid (5-HIAA). Patient specimens are stable for up to 14 days at +2 to +8 °C in amber coloured vials. |
Injection Volume | ≤ 2 µl |
Column temperature | +25 °C |
Ionisation | ESI positive |
MS/MS-Mode | MRM |
Please note | The freely available information on this website, in particular on the sample preparation, are not sufficient to work with our products. Please read instructions and warning notices on products and/or instruction manuals. |
Method of Analysis | LC-MS/MS |
Parameter | 5-Hydroxyindoleacetic Acid (5-HIAA), Homovanillic Acid (HVA), Vanillylmandelic Acid (VMA) |
-
6PLUS1® Multilevel Urine Calibrator Set VMA, HVA, 5-HIAAOrder no.: 80839
MassChrom® Biogenic Amines/Metabolites in Urine - LC-MS/MS
-
MassCheck® VMA, HVA, 5-HIAA Urine ControlsOrder no.: 0381/0382
MassChrom® Biogenic Amines/Metabolites in Urine - LC-MS/MS
-
System Check Solution SetOrder no.: 80810
MassChrom® Biogenic Amines/Metabolites in Urine - LC-MS/MS
-
Tuning Mix VMA, HVA, 5-HIAAOrder no.: 80815
MassChrom® Biogenic Amines/Metabolites in Urine - LC-MS/MS
-
Analytical Column VMA, HVA, 5-HIAA Urine - LC-MS/MSOrder no.: 80200
MassChrom® Biogenic Amines/Metabolites in Urine - LC-MS/MS