VMA, HVA, 5-HIAA Urine Calibration Standard

Order No.: 1009
Parameters:
5-Hydroxyindoleacetic Acid (5-HIAA), Homovanillic Acid (HVA), Vanillylmandelic Acid (VMA)
VMA, HVA, 5-HIAA in Urine - HPLC

VMA, HVA, 5-HIAA Urine Calibration Standard, lyophilised

For VMA, HVA, 5-HIAA and 5-HIAA in Urine by HPLC (1000/B, 51000)

This lyophilised calibrator from Chromsystems is based on human urine and should be used according to the instruction manual. It is designed to calibrate the measurement method in clinical diagnostics for the quantitative determination of VMA, HVA, 5-HIAA in urine. While following the instructions the calibrator should be handled and measured in the same manner as a patient specimen.

An alternative is the aqueous calibration standard (order no. 1003/B), which is directly injected into the HPLC system without sample preparation.

More Information
Content 5 x 5 ml (lyoph.)
Concentrations

Please note: All concentrations shown here are exemplatory. They do not reflect real data for the described products. Actual concentrations depend on the production lot of each product and can exclusively be found in the product information leaflet. Please ask for these product information leaflets or download them from the service site of the Chromsystems website.

Substance Value
(mg/l)
Vanillylmandelic acid (VMA) 9.91
5-Hydroxyindole-3-acetic acid (5-HIAA) 6.68
Homovanillic acid (HVA) 9.01
Method of Analysis HPLC
Parameters 5-Hydroxyindoleacetic Acid (5-HIAA), Homovanillic Acid (HVA), Vanillylmandelic Acid (VMA)
As a customer please login or register to gain full access.

VMA, HVA, 5-HIAA Urine Calibration Standard, lyophilised

For VMA, HVA, 5-HIAA and 5-HIAA in Urine by HPLC (1000/B, 51000)

This lyophilised calibrator from Chromsystems is based on human urine and should be used according to the instruction manual. It is designed to calibrate the measurement method in clinical diagnostics for the quantitative determination of VMA, HVA, 5-HIAA in urine. While following the instructions the calibrator should be handled and measured in the same manner as a patient specimen.

An alternative is the aqueous calibration standard (order no. 1003/B), which is directly injected into the HPLC system without sample preparation.

More Information
Content 5 x 5 ml (lyoph.)
Concentrations

Please note: All concentrations shown here are exemplatory. They do not reflect real data for the described products. Actual concentrations depend on the production lot of each product and can exclusively be found in the product information leaflet. Please ask for these product information leaflets or download them from the service site of the Chromsystems website.

Substance Value
(mg/l)
Vanillylmandelic acid (VMA) 9.91
5-Hydroxyindole-3-acetic acid (5-HIAA) 6.68
Homovanillic acid (HVA) 9.01
Method of Analysis HPLC
Parameters 5-Hydroxyindoleacetic Acid (5-HIAA), Homovanillic Acid (HVA), Vanillylmandelic Acid (VMA)