3PLUS1® Multilevel Plasma Calibrator Set Mycophenolic Acid/Glucuronide

Order No.: 46029
Parameters:
Mycophenolic Acid, Mycophenolic Acid Glucuronide
MassTox® Series A Mycophenolic Acid in Serum/Plasma – LC-MS/MS

3PLUS1® Multilevel Plasma Calibrator Set Mycophenolic Acid/Glucuronide, lyophilised

For MassTox® Series A Parameter Set Mycophenolic Acid in Serum/Plasma by LC-MS/MS (92916/RUO)

These lyophilised calibrators from Chromsystems are based on human plasma and should be used according to the instruction manual. They are designed to calibrate the measurement method in clinical diagnostics for the quantitative determination of mycophenolic acid and mycophenolic acid glucuronide in serum/plasma. While following the instructions the calibrators should be handled and measured in the same manner as a patient specimen. These calibrators are only available as multilevel calibrator set with 3 different concentration levels plus 1 blank value.

More Information
Content 4 x 1 ml (lyoph.)
Concentrations

Please note: Concentration values shown here are typical. For lot specific concentration values please refer to the product insert supplied with the materials. The product inserts can also be requested from us directly or downloaded from our website after login.

NEW: An Excel file with the data from the product information leaflet is now available in the "Downloads" section (for registered customers only). This eliminates manual data entry of large data sets.

SubstanceUnitCalibrator 1Calibrator 2Calibrator 3Blank Calibrator
Mycophenolic acid mg/l 0.97 3.89 9.46 n.d.
Mycophenolic acid glucuronide mg/l 18.2 88.3 220 n.d.

n.d. = not detected (< LOQ)

The blank level is manufactured using the same matrix pool as used for the calibrator levels 1, 2 and 3. It was not fortified with mycophenolic acid or mycophenolic acid glucuronide.

Method of Analysis LC-MS/MS
Parameters Mycophenolic Acid, Mycophenolic Acid Glucuronide
As a customer please login or register to gain full access.

3PLUS1® Multilevel Plasma Calibrator Set Mycophenolic Acid/Glucuronide, lyophilised

For MassTox® Series A Parameter Set Mycophenolic Acid in Serum/Plasma by LC-MS/MS (92916/RUO)

These lyophilised calibrators from Chromsystems are based on human plasma and should be used according to the instruction manual. They are designed to calibrate the measurement method in clinical diagnostics for the quantitative determination of mycophenolic acid and mycophenolic acid glucuronide in serum/plasma. While following the instructions the calibrators should be handled and measured in the same manner as a patient specimen. These calibrators are only available as multilevel calibrator set with 3 different concentration levels plus 1 blank value.

More Information
Content 4 x 1 ml (lyoph.)
Concentrations

Please note: Concentration values shown here are typical. For lot specific concentration values please refer to the product insert supplied with the materials. The product inserts can also be requested from us directly or downloaded from our website after login.

NEW: An Excel file with the data from the product information leaflet is now available in the "Downloads" section (for registered customers only). This eliminates manual data entry of large data sets.

SubstanceUnitCalibrator 1Calibrator 2Calibrator 3Blank Calibrator
Mycophenolic acid mg/l 0.97 3.89 9.46 n.d.
Mycophenolic acid glucuronide mg/l 18.2 88.3 220 n.d.

n.d. = not detected (< LOQ)

The blank level is manufactured using the same matrix pool as used for the calibrator levels 1, 2 and 3. It was not fortified with mycophenolic acid or mycophenolic acid glucuronide.

Method of Analysis LC-MS/MS
Parameters Mycophenolic Acid, Mycophenolic Acid Glucuronide