Basic Kit A for 200 Tests - LC-MS/MS
Part of the modular system MassTox® Series A
Provides all components required for sample prep and all mobile phases
Basic Kit for all Parameters of Series A
The Basic Kit allows the rapid quantitative determination of a multitude of substances in serum or plasma by LC-MS/MS. To perform the analysis, you will need the MassTox® Basic Kit A, the substance-specific MassTox® Parameter Set and the analytical column MassTox® TDM MasterColumn® A.
Preparation of the research samples is the same for all parameters, based on a simple, effective protein precipitation process. The use of stable isotope-labelled (deuterated) internal standards ensures high performance of the analysis.
The Basic Kit A is available for 200 and 1000 analyses.
Content:
1 x Mobile Phase 1 (92001/RUO)
1 x Mobile Phase 2 (92002/RUO)
1 x Precipitation Reagent (92003/RUO)
1 x Extraction Buffer (92005/RUO)
1 x Dilution Buffer 1 (92007/RUO)
1 x Dilution Buffer 2 (92008/RUO)
1 x Rinsing Solution (92009/RUO)
2 x Reaction vials (33006)
Method of Analysis | LC-MS/MS |
---|---|
Number of Tests | 200 |
Please note | The freely available information on this website, in particular on the sample preparation, are not sufficient to work with our products. Please read instructions and warning notices on products and/or instruction manuals. |
Sample Preparation | The sample preparation is standard for all Series A analytes.
|
Parameters | 70 grouped in 5 sets |
Basic Kit for all Parameters of Series A
The Basic Kit allows the rapid quantitative determination of a multitude of substances in serum or plasma by LC-MS/MS. To perform the analysis, you will need the MassTox® Basic Kit A, the substance-specific MassTox® Parameter Set and the analytical column MassTox® TDM MasterColumn® A.
Preparation of the research samples is the same for all parameters, based on a simple, effective protein precipitation process. The use of stable isotope-labelled (deuterated) internal standards ensures high performance of the analysis.
The Basic Kit A is available for 200 and 1000 analyses.
Content:
1 x Mobile Phase 1 (92001/RUO)
1 x Mobile Phase 2 (92002/RUO)
1 x Precipitation Reagent (92003/RUO)
1 x Extraction Buffer (92005/RUO)
1 x Dilution Buffer 1 (92007/RUO)
1 x Dilution Buffer 2 (92008/RUO)
1 x Rinsing Solution (92009/RUO)
2 x Reaction vials (33006)
Method of Analysis | LC-MS/MS |
---|---|
Number of Tests | 200 |
Please note | The freely available information on this website, in particular on the sample preparation, are not sufficient to work with our products. Please read instructions and warning notices on products and/or instruction manuals. |
Sample Preparation | The sample preparation is standard for all Series A analytes.
|
Parameters | 70 grouped in 5 sets |