6PLUS1® Multilevel Serum Calibrator Set Steroid Panel 1

Order No.: 72038
Parameters:
11-Deoxycortisol, 21-Deoxycortisol, Aldosterone, Corticosterone, Cortisol, Cortisone
MassChrom® Steroids in Serum/Plasma - LC-MS/MS

Steroid Panel 1

Aldosterone

Corticosterone

Cortisol

11-Deoxycortisol

21-Deoxycortisol

Cortisone

6PLUS1® Multilevel Serum Calibrator Set Steroid Panel 1, lyophilised

For MassChrom® Steroids in Serum/Plasma with Sample Clean Up Columns or 96 SPE Well Filter Plates (72072/C/RUO, 72072/96/RUO, 72072/480/RUO)

These lyophilised calibrators from Chromsystems are based on human serum and should be used according to the instruction manual. They are designed to calibrate the measurement method in clinical diagnostics for the quantitative determination of steroids/Panel 1 in serum/plasma. While following the instructions the calibrators should be handled and measured in the same manner as a patient specimen.
These calibrators are only available as multilevel calibrator set with 6 different concentration levels plus 1 blank value.

More Information
Content 7 x 3 ml (lyoph.)
Concentrations

Please note: Concentration values shown here are typical. For lot specific concentration values please refer to the product insert supplied with the materials. The product inserts can also be requested from us directly or downloaded from our website after login.

Substance UnitCalibrator 1Calibrator 2Calibrator 3Calibrator 4Calibrator 5Calibrator 6Blank Calibrator
Aldosterone µg/l 0.024 0.084 0.161 0.319 0.816 4.23 n.d. (< 0.014)
Corticosterone µg/l 0.455 0.997 2.39 4.86 14.9 48.1 n.d. (< 0.175)
Cortisol µg/l 9.02 20.1 39.1 77.5 149 290 n.d. (< 1.52)
Cortisone µg/l 0.942 2.56 4.93 9.66 19.5 38.8 n.d. (< 0.148)
11-Deoxycortisol µg/l 0.088 0.484 0.938 1.87 4.66 13.7 n.d. (< 0.030)
21-Deoxycortisol µg/l 0.070 0.163 0.257 0.513 1.56 4.69 n.d. (< 0.027)
 
n.d. = not determined, analytes under LOQ
Method of Analysis LC-MS/MS
Parameters 11-Deoxycortisol, 21-Deoxycortisol, Aldosterone, Corticosterone, Cortisol, Cortisone
As a customer please login or register to gain full access.

Steroid Panel 1

Aldosterone

Corticosterone

Cortisol

11-Deoxycortisol

21-Deoxycortisol

Cortisone

6PLUS1® Multilevel Serum Calibrator Set Steroid Panel 1, lyophilised

For MassChrom® Steroids in Serum/Plasma with Sample Clean Up Columns or 96 SPE Well Filter Plates (72072/C/RUO, 72072/96/RUO, 72072/480/RUO)

These lyophilised calibrators from Chromsystems are based on human serum and should be used according to the instruction manual. They are designed to calibrate the measurement method in clinical diagnostics for the quantitative determination of steroids/Panel 1 in serum/plasma. While following the instructions the calibrators should be handled and measured in the same manner as a patient specimen.
These calibrators are only available as multilevel calibrator set with 6 different concentration levels plus 1 blank value.

More Information
Content 7 x 3 ml (lyoph.)
Concentrations

Please note: Concentration values shown here are typical. For lot specific concentration values please refer to the product insert supplied with the materials. The product inserts can also be requested from us directly or downloaded from our website after login.

Substance UnitCalibrator 1Calibrator 2Calibrator 3Calibrator 4Calibrator 5Calibrator 6Blank Calibrator
Aldosterone µg/l 0.024 0.084 0.161 0.319 0.816 4.23 n.d. (< 0.014)
Corticosterone µg/l 0.455 0.997 2.39 4.86 14.9 48.1 n.d. (< 0.175)
Cortisol µg/l 9.02 20.1 39.1 77.5 149 290 n.d. (< 1.52)
Cortisone µg/l 0.942 2.56 4.93 9.66 19.5 38.8 n.d. (< 0.148)
11-Deoxycortisol µg/l 0.088 0.484 0.938 1.87 4.66 13.7 n.d. (< 0.030)
21-Deoxycortisol µg/l 0.070 0.163 0.257 0.513 1.56 4.69 n.d. (< 0.027)
 
n.d. = not determined, analytes under LOQ
Method of Analysis LC-MS/MS
Parameters 11-Deoxycortisol, 21-Deoxycortisol, Aldosterone, Corticosterone, Cortisol, Cortisone
As a customer please login or register to gain full access.